Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Below, you will find the description of parameters required for the Otalio Master plugin:

Name

Value

SERVER_NAME

Address of the server hosting the APM database

DATABASE

Enter the database name used when installing Adonis Personnel Manager.

DEBUGLOG

0 / 1 (Extended log)

SERVICE_PSW

Service password

SERVICE_URL

URL to Otalio service

SERVICE_USER

Otalio user

XREF

Interface name identifying the XREF codes used by this plugin. For more information, see

XREF_SEX_U

Additional Gender identification matching the APM value - [U] Unknown

XREF_SEX_N

Additional Gender identification matching the APM value - [N] Non-binary

SHIPCODE

Otalio’s Code of current vessel

DEBUGDAYS

The request/response files are now stored only for the specified number of days and then will be deleted.

Note: If the DEBUGDAYS parameter is not defined, files will be stored within the current day only.

ONB_CODE

GCT Code of Seaservice activity

...

APM Configuration

Adonis uses the standard XREF functionality to link the Adonis lookup tables (General codes, Organization structure) to the corresponding code in Otalio.

Expand
titleOtalio Master Interface Code Setup

To export data, it is required to define the Otalio Master plugin code reference. To do this, first, log in to the Adonis Personnel Manager. Once logged in, navigate to the Setup ribbon tab > General Codes > Miscellaneous > Interfaces and proceed with the following steps:

  1. On the ribbon, click New to make the dialog appear:

    otalio_plugin_housekeeping_gencode_interfaces.pngImage Modified

  2. Enter a Code (mandatory field), a unique alpha-numeric APM code.

  3. In the Text field, indicate the name of an interface and its alternative name, if needed, in the Alternative field.

  4. In the Sort field, define the order number of a record (where 0 means the first record in the list).

  5. In the Is Passive field, specify whether the code is to be active or passive. Passive codes appear as disabled. It is recommended to set a code to Passive if it will no longer be in use.

  6. Click OK to proceed.

 

Expand
titleLink Lookup Table to 3party Lookup
  1. Navigate to the Setup ribbon tab > General Codes >

...

  1. Personnel Details >

...

  1. Departments:

  2. Select the

...

  1. department affected and click Open on the toolbar.

  2. Switch to the XREF tab and click the Append button. Clicking the command enables the fields to be filled out:

    • Interface. Select the interface from the drop-down list. If the interface is unavailable, you need to define the interface by following the instructions in How to add an xref interface above.

    • Xref Code. Enter a cross-reference value of the 3rd party system

    • Comment. Enter any comment you want to add.

...

    • OTM_code_editor_department.jpgImage Added

  1. When completed, click OK to apply the changes.