Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Compatibility

APP 2024.20* or higher

Requirement

Dynamic Positioning Application Tablet

https://shipadmin.com/dplog.html

Description

The Dynamic Positioning Log module keeps a record of the assigned Dynamic Positioning Operators as well as time spent on their tasks. Once DP Dynamic Positioning operators are appointed in APM or crew members with DP Dynamic Positioning log certificates already available in APM, this data is sent to Ship Adminthe ShipAdmin DP Log Application. Then Ship Admin the ShipAdmin DP Log Application returns operators' tasks, Dynamic Positioning time, DP and the hotseat time spent on tasks task completion.

Info

Crew members with DP log certificates are sent to Ship Admin ShipAdmin DP Log Application notwithstanding the certificate validity status (valid or expired).

...

Info

Please be aware that the records in the Dynamic Positioning Log module become available after:

  • Sending data on the appointed DP operator who owns a respective certificate. For more information, see Competence Setup.

  • Receiving data on DP completion of Dynamic Positioning operator’s tasks completion.

For more information on API methods to be used for data exchange, see Technical Specification.

...

Info

The setup is carried out in both in the Adonis Administrator Portal and the Adonis Personnel Manager. for For more information, see APM Configuration and APP Configuration.

 

Anchor
APM_Configuration
APM_Configuration
APM Configuration

...

  1. On the ribbon, click New to make the dialog appear:

    DP_log_code_editor_interface.jpg

  2. Enter a Code code (mandatory field), which is a unique alpha-numeric alphanumeric APM code.

  3. In the Text field, indicate the name of an interface and its alternative name, if needed, in the Alternative field.

  4. In the Sort field, define the order number of a record (where 0 means the first record in the list).

  5. In the Is Passive field, specify whether the code is to be active or passive. Passive codes appear as disabled. Setting a code to Passive is recommended if it is no longer in use.

  6. In the APP Modules field, select the Adonis Personal Portal module(s) where you want to use the code.

  7. Click OK to proceed.

...

On adding the interface, it is mandatory to specify a required certificate for DP the Dynamic Positioning operator.

For To do this, log into in to Adonis Personnel Manager. Now, navigate to the Setup ribbon tab > General Codes > CompetenceCompetence Codes and proceed with the following steps:

...

Define Roles, User Groups

Once logged into the Adonis Administrator Portal, follow the directions in:

...